english

DEZEGA COMPRESSED OXYGEN SELF-CONTAINED CLOSED-CIRCUIT BREATHING APPARATUS (P-30)

DEZEGA COMPRESSED OXYGEN SELF-CONTAINED CLOSED-CIRCUIT BREATHING APPARATUS (P-30)
DEZEGA COMPRESSED OXYGEN SELF-CONTAINED CLOSED-CIRCUIT BREATHING APPARATUS (P-30)
  • Photos
  • Video
  • meadi item

Use

The P-30 is used in case of emergencies and in the event of exposure to an irrespirable atmosphere.

description

P-30 can be used at ambient temperature from –20 оС to +60 оС and relative humidity up to 100 % while the temperature is  
40 °С and atmosphere pressure is  70-125 kPa.

TECHNICAL DATA

Rated duration with moderate working conditions, hours 4
Weight w/o face mask (fully-charged oxygen cylinder), fully equipped,  
Without ice and cooler cover, kg 11,7
With ice and cooler cover, kg 12,5
Full-face mask / mouthpiece weight,kg 0,7 / 0,16
CO2 absorber weight, kg 2
Oxygen reserve, l 400
Working pressure, MPa 20
Low pressure signal device operating pressure, Mpa 5,5
Continuous oxygen supply, l/min 1,4
Bypass valve oxygen supply, l/min 150-60
Demand valve oxygen supply, l/min 70
Lung demand valve opening pressure, Pa -100…-300
Relief valve opening positive pressure, Pa 100…300
Breathing bag volume, l 5
Dimensions, mm 450х375х165